Impeller Kit CEF Inboard Engine 500107.GT
Returns policy
T & Cs
CEF impellers are affordable yet great products designed for the budget-conscious customer. Made in Italy for popular water pump brands, inboard engines, water cooling pumps, and outboard motors.
DIMENSIONS: A inner/outer 14.29mm/16mm, B: 57mm C: 31.6mm
BLADES: 12
For Model types:
Volvo Penta
Replaces: 3862281 875811-2 877400 21951346 3858256 3862567 3855546 3856039 21951348
JABSCO
Replaces: 1210-0001 3085-0001
JOHNSON
Replaces: 09-1027B
Yanmar
Replaces:127610-42270 129470-42530 129470-42531 129470-42532
Vetus Replaces: 201 Ancor 50007
Perkins Replaces:0460038 24880190
Oban Replaces;132-0162 Aifo 4913429
Yamaha/Sole Replaces: 351.11.008
Comes with Gasket & Plug
How to remove an old impeller:
Remove the impeller with slip joint pliers or a Johnson Pump Impuller
How to fit a new impeller:
Lubricate the shaft and the inside of the pump body and the end cover. Use Johnson Pump Lubrication to help develop prime and prevent damage from dry-running the pump at initial start-up. Mount the impeller by making a pushing and twisting movement in the rotating direction. Lubricated impellers should not be stored for extended periods of time. The engine should be run after installation of a new impeller to wash out the lubrication. These recommendations apply to any service work on the pump and its components that require the use of lubrication inside the pump for assembly and start-up.
Warning! Do not use any petroleum-based products to lubricate the inside of the pump. Only use Johnson Pump Lubrication. Other products can damage the impeller, which will damage the pump and lead to engine failure. Do not run the impeller without water or lubricant; this can cause engine failure or a fire.
1. A vacuum is created as the flexible impeller vanes straighten upon leaving the cam, drawing liquid into the pump.
2. The rotating impeller carries liquid from the inlet to the outlet port. As a consequence of their design, flexible impeller pumps can pass fairly large solids.
3. When the flexible impeller vanes regain contact with the cam, they bend and the liquid is discharged from the pump in a uniform flow. Liquids can be pumped in the opposite direction by reversing the rotation of the pump.